Statim 2000 Owners Manualclevervia

Free Statim 2000 Operational Manual Click Here For Your Free Statim 2000 Operational Manual AllClaveParts.com - Autovlave Repair Made Simple is not eBay sellers who do not have a clue about. IM 2000 G4 Cassette 4.2 Using the STATIM 5000 G4 Cassette 4.3 Using Drying Plates with the STAT IM 5000 G4 4.4 Preparing and Loading Instruments 4.5 Using Biological and Chemical Indicators 4.6. STATIM 2000 Laboratory Equipment pdf manual download. Also for: Statim 2000s, Statim 2000 g4. STATIM Cassette Autoclave and Statim are registered trademarks and STAT-DRI, Your Infection Control Specialist, and DriTec logos are trademarks trademarks referred to in this manual are the property of their respective owners. The new Statim 2000 G4 has an integrated data logger, with results accessible via a USB port. Availability – There is a robust secondary market for Statims, so it’s not hard to find a great deal on a refurbished unit. Cons: Cost to own – The Statim’s gasket costs twice as much as a Tuttnauer gasket and needs to be replaced twice a year. Statim 2000 Will Not Power Up - When your Statim 2000 will not turn on If nothing comes on when you turn it on.and your Statim 2000 Autoclave seems to be lifeless, then this is where to start It is important you determine which software version your Printed Circuit Board is using before proceeding.

Fast, Gentle, Reliable, and Smart.

STATIM is the world’s fastest cassette autoclave from start to sterile, gentle on your instruments due to its patented steam process and relied upon by the busiest of practices.

Drawing on over 25 years of innovation, the leader in autoclave technology has created a complete line of STATIM Cassette Autoclaves – designed to meet the needs of every size of practice. The STATIM family comprises the fastest, most innovative cassette autoclaves available on the market today.

Fast

STATIM provides sterilization and dryness at speeds faster than conventional chambered autoclaves.

Manualclevervia
  • Using only a small amount of water for each cycle, the STATIM heats and converts to steam in mere seconds.
  • The innovative design of STATIM’s fully removable chamber allows for quick heating and cooling.
  • A complete solution: rapid sterilization with rapid drying via the STATIM Dri-Tec drying technology.

Smart

G4 Technology – information at your fingertips.

  • WiFi enabled G4 technology can connect and send cycle data to your smart devices or computer, allowing staff to focus on the most important thing in a dental practice, the patients.
  • Maintenance reminders, instructions and the option for automatic software updates keep your STATIM in good working order.
  • G4 technology connects your STATIM to specialized technicians, which allows for remote support and minimizes unnecessary downtime.

Reliable

For over 25 years, STATIM’s speed, reliability and dependability have made it the ideal sterilizer for every practice.

  • Healthcare practitioners in over 90 countries around the world rely on STATIM to protect their patients and staff from infection.
  • The spirit of innovation that made STATIM an integral part of every Stericentre over 25 years ago is still evident with the technological advancements like G4 technology that bring automation to the Stericentre.
  • Whether as a stand-alone product or in combination with the Bravo Chamber Sterilizer, dentists rely on STATIM for fast and efficient instrument turnaround.

STATIM G4 Sterilization Cycle Specifications

STATIM G4 Technical Specifications

DOWNLOAD

STATIM FAQs

ACCESSORIES available in the Shop:

  • 01-100204S Exhaust tube
  • 01-103945S Instrument rack for unwrapped instruments
  • 01-106653 Instrument rack for wrapped instruments
  • 01-101783S Water reservoir cap & filter
  • 01-109300S Water reservoir filter

The use of STATIM sterilizers was introduced to the body art field in the early 1990’s by Brian Skellie at Piercing Experience, and developed in community along with other practical innovations in applied safety precautions and techniques.

Q: What type of water do I use with Statim?

A: Always use steam-distilled water in the Statim Cassette Autoclave. Other water sources will damage the unit and void the warranty. The VistaPure is an exception, as it filters tap water to the correct level of purity for Statim, Bravo and StatClave.
back to top

Q: How do I test the quality of distilled water?

A: If purchasing distilled water, SciCan recommends using a water conductivity tester (SciCan part no. 01-103139S) to check for impurities. Contact us for more details.

If you would like to produce your own safe distilled water, take a look at SciCan’s AquaStat water distiller. It is a green and efficient way to make one gallon of perfect water for your autoclave or drinking purposes, quickly and for pennies.
back to top

Statim 2000 Manual Pdf

Q: How do I prepare instruments for use with Statim?

A: Thoroughly wash, rinse, and dry all instruments before inserting into the Statim. A HydrIM automated instrument washer does this efficiently and reliably.
back to top

Q: How often do I clean the interior and exterior of the cassette?

A: Keeping the Statim cassette clean is good clinical practice. The interior surface of the cassette should be cleaned at least once a week with a mild, chlorine-free dishwashing soap. To promote quick drying, we recommend spraying the cassette lid and tray with Stat-Dri after each cleaning. For detailed instructions concerning cassette cleaning and the use of Stat-Dri, see the Statim Operator’s Manual.
back to top

Q: What do I do if steam or a puddle of water is detected during or after a cycle?

2000

A: If steam or a puddle of water is detected during or after a cycle, check the cassette seal. This problem may be corrected by doing the following:
a) Replacing the seal if it is older than six months or has been used for more than 500 cycles.
b) Cleaning the outside edge of the tray.
c) Checking the seal for damage and/or misalignment.
d) Checking the cassette tray and lid for misalignment [Read more]
back to top

Q: What if I receive an error code?

A: If the LCD displays a NOT STERILE message, note the error code and consult the Troubleshooting section of your Operator’s Manual. Contact us for further assistance.
back to top

Q: Do I need to ensure that the Statim is level before operating?

A: Yes. Before operating your Statim autoclave, make sure it rests on a flat and level surface. If you are uncertain, the level indicator on the front panel and leveler feet underneath the unit will help you correct any problems. (Align the bubble in the level indicator to the right front quadrant of the target.)
back to top

Q: What do I do if my Statim has not been run for several days?

Statim 2000 Maintenance Manual

A: If you do not operate your Statim autoclave for several days, run two wrapped instrument cycles. Conduct a thorough cassette cleaning and rinse, and apply Stat-Dri to the cassette tray and lid after cleaning.
back to top

2000

Q: How should I drain the reservoir?

A: To empty the reservoir, use the drain tube. If your Statim does not have a drain tube, a hand pump will suffice. Except when filling or emptying the reservoir, keep the reservoir cap securely fastened at all times.
back to top

Q: What should I do if the Statim is on, but not in use?

A: If your Statim is powered ON but not in use, pull the cassette 1-2cm out of the unit. This will make the unit inactive until the cassette is reinserted and will prolong the life of your unit. Be careful to position the unit so as not to bump into the cassette.
back to top

Q: How do I recognize whether my filter(s) needs replacement?

Statim 2000 User Manual

A: Monitor the white air filter and the bacteria-retentive filter at the back of the unit. A dirty filter will cause poor drying. If the filter has turned gray, it is in need of replacement (see the maintenance section of the Operator’s Manual).
back to top

Q: How do I transport my Statim?

Statim 2000 Manual

A: Whenever you need to transport your Statim, make sure you empty the water reservoir and screw-in the feet. Repack your Statim in the original packing materials to reduce any damage, and don’t forget to include the country kit, cassette and waste water bottle.
back to top

Comments are closed.